By inputting the major design criteria,
you can solve for overall
DAF sizing based on fluctuating solids loading.
The spreadsheet operates on Microsoft Excel 2003 or later.
Below is a sample shot of the spreadsheet.
|
Hydro-Flo Technologies, Inc. |
|
|
The Art and Science...
of Wastewater Treatment |
|
|
For more detailed information go to
www.HydroFloTech.com |
|
Available
DAF Model #'s |
|
|
Company |
|
5 |
281 |
|
|
Location |
|
8 |
300 |
|
|
|
|
11 |
320 |
|
This spreadsheet will calculate a DAF unit based on ppm of
TSS & FOG combined, Flow rate and acceptable A/S ratio: |
|
|
15 |
340 |
|
|
|
20 |
361 |
|
|
|
|
25 |
383 |
|
|
Input |
|
31 |
405 |
|
What is the combined TSS & FOG ppm content of wastewater: |
3000 |
|
38 |
428 |
|
What is the process flow rate (gpm): |
250 |
|
45 |
451 |
|
Lbs/Sq. Ft./Hr (1.5 Typical) |
1.5 |
|
53 |
475 |
|
Recycle System Pressure (in gage pressure, psi, typically 65
psig) |
80 |
|
61 |
500 |
|
Recycle System Efficency (Typically 80.00%) |
80% |
|
70 |
527 |
|
Temperature (in Farenheit) |
60 |
|
80 |
592 |
|
Selected DAF model number based on minimum required DAF unit
(below) and round up to the next larger DAF model |
263 |
|
90 |
661 |
|
|
|
101 |
735 |
|
|
|
|
113 |
815 |
|
Call 630-762-0380 to talk to a Hydro-Flo application
engineer |
|
125 |
900 |
|
|
|
|
138 |
1,088 |
|
|
Output |
|
151 |
1,191 |
|
lb/gal of TSS = |
0.03 |
|
165 |
1,301 |
|
Solids Loading ratio of TSS per min (lb); |
6.26 |
|
180 |
1,416 |
|
Solids Loading ratio of TSS per hour (lb): |
375.50 |
|
195 |
1,539 |
|
Solids Loading ratio of TSS per day (24 hr period): |
9012.10 |
|
211 |
1,668 |
|
Saturation Concentration (lb air/gal H2O) at atmospheric
pressure |
0.0002190 |
|
228 |
1,805 |
|
Theoretical Air Release (lb air/gal H2O) |
0.0009098 |
|
245 |
1,945 |
|
Minimum required Sq. Ft. in DAF Unit (Separation Chamber): |
250.34 |
|
263 |
2,150 |
|
gpm/sq.ft. hydraulic loading rate for Selected DAF Alone |
0.95 |
|
|
|
|
|
|
|
|
|
|
Recirculation (RAD) Flow Rate Range |
|
|
|
|
|
Theoretical Low End Recycle (RAD) Flow Rate (gpm): |
125.00 |
|
Listed at the left are the theoretical RAD flow rates.
If these numbers are above 4, increase the selected DAF
model # until the output (at the desired recycle rate) is
less than or equal to 4 |
|
Low end gpm/sq.ft. hydraulic loading rate for selected
DAFand theoretical RAD combined (gpm/sq.ft.): |
1.4259 |
|
| |
|
| |
|
|
|
Theoretical High End Recycle (RAD) Flow Rate (gpm): |
275.17 |
|
|
High end gpm/sq.ft. hydraulic loading rate for the selected
DAFand theoretical RAD combined (gpm/sq.ft.): |
1.9968 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CRITERIA: You must apply the following
when sizing a DAF |
|
|
Standard Solids Loading Rate: 1.5 lb/sq. ft./hr |
|
|
|
|
|
Never use more than 4 gpm/sq.ft hydraulic loading rate for
the DAF and RAD combined |
|
|
|
|
Acceptable Lbs Air/Lbs Solids range = 0.015 - 0.040 |
|
|
|
|
|
We typically apply 100% of the low end RAD flow rate when
BELOW - 3000 ppm |
|
|
|
|
We typically apply 75% of the high end RAD flow rate when
BETWEEN 3000 - 5000 ppm |
|
|
|
We typically apply 100% of the high end RAD flow rate when
ABOVE - 5000 ppm |
|
|
|
|
|
|
|
|
|
|
Formulas: |
|
|
|
|
|
Recirculation Flow Rate: |
|
|
|
|
|
(Lbs Air/Lbs Solids) x (Solids Loading Rate/min) x
Theoretical Air Release |
|
|
|
|
Dimensions for (Solids Loading Rate/min): Lbs/min |
|
|
|
|
|
Dimensions for Theoretical Air Release: 1000 gal/0.62 lbs.
@ 75 psig and 68 degrees F |
|
|
|
Low end (Lbs Air/Lbs Solids) = 0.015 |
|
|
|
|
|
High end (Lbs Air/Lbs Solids) = 0.040 |
|
|
|
|
|
|
|
|
|
|
|
Conversion Factors: |
|
|
|
|
|
1,000 mg = 1 gr |
|
|
|
|
|
453.59 gr = 1 lb. |
|
|
|
|
|
3.785 l = 1 gal. |
|
|
|
|