Hydro-Flo Technologies, Inc.  The Art and Science of Wastewater Treatment

                  TECHNOLOGIES, INC.           The Art and Science... of Wastewater Treatment

A "Green" company
 since 1990

                   

HFT HOME

Hydro-Flo Technologies, Inc

Products

Batch and Continuous Flow Chemical Reaction Systems

pH adjustment, neutralization, precipitation and specialty chemical reaction systems

Clarifiers

Inclined Plate (IPC) Clarifiers

Control Panels

World class PLC and relay logic based panels

Flotation Systems

Traditional and lamella plate dissolved air flotation (DAF) systems

Media Filters

Sand (deep bed and high rate), multi-media and specialty filters

Media Packs

Media Packs for oil / water (immiscible liquids), DAF, sedimentation and custom separation systems

Oil Water Separators

API, enhanced gravity and pressurized separators suitable for any application

Packaged Systems

Pre-packaged turnkey systems for hundreds of applications

Pump Packages

Centrifugal, positive displacement and progressive cavity pump packages

HFT....

About Us

Company Profile

Customer List

Contact Us

Phone, E-mail, Fax, Etc...

Why Choose
Hydro-Flo Technologies

Request a Quote

E-Mail this page

E-Mail Us

 

 

Engineering Tools

Typical Applications

Follow this link to our library of application P&ID's and process descriptions

Application Questionnaire

Follow this link to our equipment application questionnaire

Clarifier Sizing information

Inclined Plate Clarifier Design Parameters
Detailed information on the design and sizing of inclined plate clarifiers and clarification systems

Dissolved Air Flotation System Design & Sizing information

Dissolved Air Flotation Design Parameters
Detailed information on the design and sizing of dissolved air flotation separators and separation systems

Oil Water Separator Design & Sizing information

Oil Water Separator Design Parameters
Detailed information on the design and sizing of oil water separators and separation systems

Misc Info, Data, Spreadsheets & Calculations

EPA Non-Polar Oil Test Methods

Fluid Mechanics

Reynolds Number Calculations

Water Hammer Calculations

HFT Quality Control

HFT Quality Assurance Plan

Steel Fabrications

Leak Test Certification

Interior Coatings

Exterior Coatings

Control Panels

Chemical / Material Compatibility Data

Chemical Pump Dosing Rates

Chemical Compatibility Chart

Properties of Plastic

Coating / Materials Data

Surface Prep Definitions

Gel Coat Cut Sheet

FRP Resin Cut Sheets

PDF Format

Word Format

Batch pH Adjustment SystemBatch
pH Adjustment System

Engineering Specifications

1.                           APPLICATION

1.1.                    Overall Process Description

1.1.1.                    The batch pH adjustment system will be designed to adjust the pH of a specific volume of process water, wastewater or potable water stream to a specific set-point.  The reaction tank will measure the incoming pH, mix the contents and automatically inject "acid" or "caustic" until the contents reach the desired set-point.

1.2.                    Required System Performance

1.2.1.                    The batch pH adjustment system shall adjust the pH of a set volume of water to the system set point.  Where the pH of the system influent is ????.  The treated water shall achieve a pH of ???? plus or minus ????.

2.                           SCOPE

2.1.                    The Skid

2.1.1.                    A steel skid is provided for supporting the entire system. The skid  features a welded 4" steel "C" channel frame, a 1/4" steel deck plate. 

2.1.2.                    A containment / drip pan shall be provided for protecting the steel skid from leaking or spilled corrosive fluids.  A drain connection will be provided for plumbing the containment pan to a suitable location. The pan will be fabricated from polypropylene, stainless steel, etc., and features 8" high walls.

2.2.                    Reaction Tank

2.2.1.                    A reaction tank is provided with ???? gallon capacity.

2.2.2.                    The reaction tank will be manufactured of HDPE polypropylene.  The tank will be designed for fluids with a s.g. of up to 1.9 with a safety factor of 2:1.  The tank will have provisions for positive ventilation.  The top will be designed to support all mounted equipment and the weight of one 200 lb. man without significant deflection.

2.3.                    Chemical Feed System

2.3.1.                    Two (2) chemical metering pumps (LMI or equal) will be provided for the addition of acid and caustic.  The pumps will come equipped with manual control for stroke length (20-100%) and stroke frequency (5-100 per minute).

2.3.2.                    One (1) pH probe (Signet or equal) will be provided.

2.3.3.                    One controller (Signet or equal) will be provided, with LCD display of 0-14 pH range.  The controller is to be installed in a NEMA 4 control panel.

2.3.4.                    The pH controller will turn the acid or caustic pump on/off via set points.

2.4.                    Control Panel

2.4.1.                    One (1) system control panel is provided with function selector switches, pilot lights, relays, motor starters, and circuit breakers.  Panel includes a safety disconnect switch.  The motor contactors/starters shall be provided with re-settable thermal overload protection.  The control panel will be pre-mounted and wired.

2.4.2.                    Available Power = ???? V, ???? Hz, ???? phase

2.4.3.                    NEMA Rating:  NEMA 4, suitable for outdoor installations

3.                           GENERAL Specifications